广州伟伯科技有限公司
您的位置:首页 > 产品中心 > 痕量金属1-WS
产品搜索:

痕量金属1-WS

Trace Metals 1-WS
产品编号:3253845
规格:Proficiency Testing Material
包装规格:20 ML
产品类别:进口试剂
品牌:Supelco
优惠价:立即咨询
产品价格
产品编号包装单位单价(元)国内现货国外库存询价单
325384520 ML1210
产品别名

痕量金属1-WS

Trace Metals 1-WS

WS-Trace Metals 1

基本信息
NACRES
NA.24
General description【一般描述】
Trace Metals 1 - WS proficiency testing material is produced in accordance with ISO/IEC 17043:2010. Also referred to as Potable Water or Water Supply sample, this sample is produced according to TNI requirements. However, please note, this sample may include non-TNI analytes as well. The lower criteria from the TNI tables mimic the levels common to drinking water samples. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both.

Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. Most water PT samples are available as concentrates or ready-to-use volumes giving the end-user flexibility in selecting samples that will fit their exact needs. Our WS program is designed to meet the quality assurance requirements in compliance with the Safe Drinking Water Act (SDWA), thereby ensuring the analytical competence of your laboratory or drinking water facility.
These samples are typically provided in duplicate for use in case of lab mishap, for QC purposes or to analyze multiple methods.

Type of PT Scheme: Water analysis - Water Supply (WS)

Matrix: Water Supply/Drinking water

Analyte/s: Values of analytes vary lot to lot.

All information regarding the use of Trace Metals 1 - WS can be found in the reporting packet which will be available to download at PT Portal.
Application【应用】
Trace Metals 1 - WS is a potable water PT standard, suitable for testing trace metals in water supply/drinking water.

Have any questions? Explore our FAQs.
For more information on this product, please contact our PT Service Team
Features and Benefits【特点和优势】
We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.

Our proficiency testing (PT) program is a benchmark to:

  • provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process
  • provide a comparison of performance with that of other laboratories, nationally and internationally
  • test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems
  • provide an independent evaluation of laboratory performance
  • demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality

Preparation Note【制备说明】
Description

  • This PT sample is packaged as a 20 mL concentrate.
  • The solvent for this sample is 5% nitric acid by volume in DI water.
  • The PT sample has not been preserved.

Sample Preparation

  • Partially fill a 1000 mL volumetric flask with reagent-grade water (near 20 ℃) and add 1 mL of trace-metal-grade nitric acid.
  • Open ampule PE1488-20ML (be careful to avoid cuts on glass) and transfer 10.0 mL of concentrate to the volumetric flask.
  • Fill the flask to volume with reagent-grade water and mix well.
  • The sample is now ready for immediate digestion and analysis, as per laboratory SOPs.
  • A reagent-grade blank should be analyzed concurrently for background correction. The water blank should be made to match the acid matrix of the standards and samples.

NOTE: The 0.15% v/v nitric acid specification is a minimum; the amount and type of acid may be altered to routine analytical procedures if needed.
NOTE: Mercury can be present as both inorganic and organic mercury.
Other Notes【其他说明】
Are you new to Supelco® Proficiency Testing? Be sure to register your account details in the PT Portal before placing your order.
This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma.com.

When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.
Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.

Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes.

Proficiency Testing Schedule (2021-2022)

Drinking Water
WS21-2March 24 - May 7, 2021
WS21-4 September 22 - November 5, 2021

WS22-2March 23 - May 6, 2022
WS22-4 September 21 - November 4, 2022
Legal Information【法律信息】
Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany
产品性质
Quality Level【质量水平】
100
packaging【包装】
ampule of 2 × 20 mL
concentration【浓度】
in nitric acid
application(s)
environmental
format【格式】
matrix material
产品说明
Storage and Stability【储存及稳定性】
Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.
安全信息
Pictograms【象形图】
GHS05
Signal word【警示用语:】
Danger
Hazard Statements
H290 - H315 - H318
Precautionary Statements
P234 - P264 - P280 - P302 + P352 - P305 + P351 + P338 - P332 + P313
Hazard Classifications【危险分类】
Eye Dam. 1 - Met. Corr. 1 - Skin Irrit. 2
Storage Class Code【储存分类代码】
8B - Non-combustible, corrosive hazardous materials
WGK
WGK 1
广州伟伯科技有限公司 版权所有 CopyRight ©2006-2024, All Rights Reserved
工信部备案号:粤ICP备08114744号   Page Run Time: 0.0126